About this guide
This guide is intended for two audiences:
PACS Administrators — Section 1 covers everything needed to configure and verify the integration. Section 3 covers troubleshooting.
Radiologists — Section 2 covers the day-to-day workflow once the integration is live.
Prerequisites: Windows workstation, Google Chrome, PowerScribe® 360 Reporting or PowerScribe® One installed, Vault background service (Workflow and Reporting Native Application) and Stratus Imaging Display Manager Chrome extension installed.
Section 1: PACS Administrator Setup | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
The Workflow and Reporting platform now supports integration with PowerScribe® 360 Reporting and PowerScribe® One, by Nuance Communications, Inc., as the external dictation and reporting solution. This section covers the steps required to configure and verify the integration. All steps in this section are performed before radiologists begin using the integration. | ||||||||||||||||
1.1 Enable PowerScribe in Facility Settings | ||||||||||||||||
The first step is to enable PowerScribe as the external reporting platform for the facility.
| ||||||||||||||||
What to expect after enabling
| ||||||||||||||||
1.2 Workstation Requirements | ||||||||||||||||
The integration is supported on Windows workstations and requires local installation of the following:
Contact Support for installation details. | ||||||||||||||||
Notes
| ||||||||||||||||
1.3 Verify the Workstation Setup | ||||||||||||||||
Before radiologists go live, confirm the following on each workstation: | ||||||||||||||||
| ||||||||||||||||
1.4 How Status Updates Flow | ||||||||||||||||
Understanding the status flow helps when troubleshooting or answering radiologist questions. | ||||||||||||||||
|
Section 2: Radiologist Workflow |
|---|
Once your workstation is configured by IT, no additional setup is required. This section describes your day-to-day workflow with PowerScribe enabled. |
2.1 Logging In |
|
Note
|
2.2 Opening and Dictating a Study |
|
Auto-launch rules
|
2.3 Signing a Study |
When you select Final in PowerScribe, the following happens automatically:
|
Study locked during processing The study is locked between signing and receipt of the final report. No actions can be taken on it during this window. |
2.4 Switching Between Studies |
If you open a second study while PowerScribe is open on another:
If you switch back to a previously viewed study tab and it no longer matches what is open in PowerScribe, a warning will appear: Warning: Patient context mismatch detected The study open in the platform does not match the study open in PowerScribe. • Cancel — stay on the current study without changing PowerScribe. • Relaunch — trigger PowerScribe to reopen in context with the currently active study. |
2.5 Logging Out |
When you log out of the platform, Vault automatically closes PowerScribe. No manual steps are required. |
Section 3: Troubleshooting | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
If something is not working as expected, the table below covers the most common issues and where to start. For issues not resolved here, contact support. | ||||||||||||||
|